Accuracy (cont’d)
All Models (cont’d)
Accuracy of Frequency Ranges
Display Range Accuracy
9.999 Hz ± (0.03% + 0.003 Hz)
99.99 Hz ± (0.03% + 0.03 Hz)
999.9 Hz ± (0.03% + 0.3 Hz)
9999 Hz ± (0.03% + 3 Hz)
99.99 kHz ± (0.03% + 0.03 kHz)
999.9 kHz ± (0.03% + 0.3 kHz)
Frequency—Logic Level Hz (mV Function)
Range Accuracy
Sensitivity
(square wave)
5.0 Hz to 9.999 Hz ± (0.03% + 0.002 Hz)
3 V peak
99.99 Hz ± (0.03% + 0.02 Hz)
999.9 Hz ± (0.03% + 0.2 Hz)
9999 Hz ± (0.03% + 2 Hz)
99.99 kHz ± (0.03% + 0.02 kHz)
100.0 kHz to 500.0 kHz ± (0.03% + 0.2 kHz)
500.0 kHz to 999.9 kHz ± (0.03% + 0.2 kHz) 5 V peak
Non-contact Electric Field Detection (EF)
Typical Voltage Bar Graph Indication* Frequency Range
10 V to 36 V –
50 Hz to 60 Hz
23 V to 83 V – –
59 V to 165 V – – –
124 V to 330 V – – – –
250 V to 1000 V – – – – –
*
Bar graph indication and tone are proportional to signal strength